Complete electrical and mechanical overhaul on a FIN-FAN Cooler Motor

What does a complete electrical and mechanical overhaul look like on a FIN-FAN Cooler Motor?

 
Site services
Case Studies
News
Careers
Contact
 WORKSHOP ENGINEERING STORE
Post preview
Complete electrical and mechanical overhaul on a FIN-FAN Cooler Motor

The Challenge: A 5.5kW Nidec Leroy-Somer motor (Frame size: LS 160ML, 380 Volts) in service since 1982, arrived into our Workshop with rust damage, broken bolts in the NDE bearing housing, worn bearings, damaged power cables, and an old cooling fan cover.

What We Did:
✅ Full strip-down & sandblast of fan and motor.
✅ Carried out electrical test: Surge, Megger, resistance & interturn tests on stator windings.
✅ Removed broken bolts & refurbished/machined the NDE bearing ✅ housing.
✅ Replaced bearings, seals, power cables & cooling fan cover.
✅ Dynamic balancing of both rotor and fan assembly.
✅ Complete reassembly & final test entire unit.
✅ Full repaint & delivery to site.

This cooling fan was dynamically balanced to G2.5, exceeding the standard G6.3, and the bearing housing was refurbished to H6 tolerance, all fully documented and completed using calibrated instruments

Connect with our Sales Team today and find out how our Workshop can support your business:
CORK:ย +353 22 47477